Reporting tool for treatment partners 
Login -  Treatment partner A 
  Demo  
Treatment results De-pollution results Sampling results Packages Tasks Summaries
 Treatment results 
 Evaluation 
Compare Logout en
  (11:57)What is the WF-RepTool? (principles, overview)
 More information on the WF-RepTool
 What are the buttons in the main menu?
  (00:51)Help feature within the program
Back to WF-RepTool administration
Active report    Id 25    cooling appliances (all)  Annual data 2013  Weight (kg)  1.234.000
First fractions Overview Graph Final Calculation Analyze Inspect Usage

Report - Id 25  Download for multiple use
 Remove acceptor's names
 Remove acceptor's countries
 Remove acceptor's regions
 Remove remarks on acceptors
  
 Symbol ´Speaking bulb´
  (07:23)How to work with controller remarks?
 Symbol ´Envelope´
 Report information in headline / beside envelope
 Entries in report heading section
 Symbol ´Download´ (beside report Id)
  (03:07)Options to download data
Created by: Reporter 15-12-2011, Date of background lists: 21-11-2011
copied to 35
Report type Treatment results Calc. model WEEE-Dir. 2002/96/EC, WFD 2006/12/EC
Company Treatment partner A WEEE-system DEMO system
Agent
Input fraction cooling appliances (all) Weight (kg) 1.234.000 (1.221.758)
Input remarks regular mix Period 2013
Kind of data Annual data Status done (Done by: WeeeSys 06-01-2014)
Kind of data remarks Calculation model 1
DEMO DATA - 2-step treatment (dismantling + step 1, step 2 shredding); show deduct option with municipal waste
Group
First technology used shredder for cooling & freezing appliances / separation
Attachments
 
PDF
 Overview
 Remarks from controller
 Full info (remarks, etc.)
 Warnings from automatic inspection
 
 
 Final
 Calculation - national
 Calculation - model
 exclude confidential data 
Excel
 Overview (all)
 Remarks from controller
 
 
 Rates per fraction - national
 Rates per fraction - model
 Final
 Calculation - national
 Calculation - model
 exclude confidential data 
Options
   Sort by percent of total input weight
   Full info (remarks, etc.)
   Warnings from automatic inspection

 
All fractions, acceptors/technologies and composition-data  (total of first fractions: 100,0000 % / 1.234.000 kg) 
  (00:53)´Overview´ - the treatment tree, downstream documentation
  (00:53)Options for ´Sort by relevance´ and ´Full info´
  (01:10)Features in the ´Overview´ - arrow: jump, stars: climb
  (00:51)Option to collapse and expand
  (00:58)Use of package marked in report
  (00:46)Overview´ - red frames
  (00:46)Overview´ - red shades - manual re-calculation
  (01:57)Automatic re-calculation of results
 Where are recycling and recovery rates shown?
  (00:27)How to check if a report is finished?
  (00:50)Set report to ´Done´
 
 collapseWF-RepTool codeOutput fractionInternal name and code of output fractionPercent Weight % [i] 
 collapse *14 06 01* / 01-1 CFC, HCFC, HFC, HC (step 1)1,2156 %15.000 kg1,2277 %
  abcd (DE)hazardous waste incinerationF100,0000 %15.000 kg1,2277 %
   plastics / organic fractions(H)(C)FC fractions > destruction TDTD100,0000 %15.000 kg1,2277 %
 
 collapse *16 02 09* / 02 PCB (suspect) capacitors0,0100 %123 kg0,0101 %
  HWI 1 (nat. market)hazardous waste incinerationF100,0000 %123 kg0,0101 %
   mixed fractions - disposalno use - 'hot technologies' TDTD100,0000 %123 kg0,0101 %
 
 collapse *16 02 11* / 02 mix of 'cabinets' containing PU foam insulation (all - CFC/HCFC and HC)input step II74,9595 %925.000 kg75,7106 %
  intern (nat. market)shredder for cooling & freezing appliances / separationI100,0000 %925.000 kg75,7106 %
 
 collapse **14 06 01* / 02-1 CFC, HCFC, HC (step 2)1,0000 %9.250 kg0,7571 %
  abcd (DE)hazardous waste incinerationF100,0000 %9.250 kg0,7571 %
   plastics / organic fractions(H)(C)FC fractions > destruction TDTD100,0000 %9.250 kg0,7571 %
 
 collapse **19 12 02 / 01-2iron fraction 'pure'Fe-shredder50,0000 %462.500 kg37,8553 %
  div. steel mills (EU/EFTA)steel mill 'traditional'F100,0000 %462.500 kg37,8553 %
   Fe / stainless steelFe > Fe recovery MRMR100,0000 %462.500 kg37,8553 %
 
 collapse **19 12 03 / 02-2mix of non-ferrous metals 'pure'Al-shredder4,0000 %37.000 kg3,0284 %
  Separator B (DE)separationI100,0000 %37.000 kg3,0284 %
 
 collapse ***19 12 03 / 03-2aluminium fraction 'pure' 95,0000 %35.150 kg2,8770 %
  diff. smelters (EU/EFTA)Al smelterF100,0000 %35.150 kg2,8770 %
   AlAl > Al recovery MRMR100,0000 %35.150 kg2,8770 %
 
 collapse ***19 12 03 / 05-2copper and copper alloys 'pure'5,0000 %1.850 kg0,1514 %
  diff. Cu smelters (EU/EFTA)Cu smelter 'traditional'F100,0000 %1.850 kg0,1514 %
   CuCu > Cu recovery MRMR100,0000 %1.850 kg0,1514 %
 
 collapse **19 12 04 / 02-1hard plastics 'pieces' 'not pure' - below ROHS/REACH valuesplastics fraction20,0000 %185.000 kg15,1421 %
  plastics cond. xy (AT)plastics conditioningI100,0000 %185.000 kg15,1421 %
 
 collapse ***19 12 04 / 02-2hard plastics 'pieces' 'pure' - below ROHS/REACH valuesother plastics30,0000 %55.500 kg4,5426 %
  plastics rec1 (AT)plastics recyclingF100,0000 %55.500 kg4,5426 %
   plastics / organic fractionsplastics > production of plastics or granulates MRMR100,0000 %55.500 kg4,5426 %
 
 collapse ***19 12 04 / 03-2plastics 'pieces' PS 'pure' - below ROHS/REACH valuesPS55,0000 %101.750 kg8,3282 %
  plastics rec2 (CN)plastics recyclingF100,0000 %101.750 kg8,3282 %
   plastics / organic fractionsplastics > production of plastics or granulates MRMR100,0000 %101.750 kg8,3282 %
 
 collapse ***19 12 10 / 01mixture of combustible wastes - conditioned for incineration - no hazardous substances and plastics below ROHS/REACH valuesincineration plastics10,0000 %18.500 kg1,5142 %
  business incinerator A (AT)co-incineration - with ERF100,0000 %18.500 kg1,5142 %
   plastics / organic fractionsplastics > used for fuel substitution ERER100,0000 %18.500 kg1,5142 %
 
 collapse ***19 12 12 / 01residues from separation - no hazardous substances and plastics below ROHS/REACH values5,0000 %9.250 kg0,7571 %
  MWI Z (AT)municipal waste incinerationF100,0000 %9.250 kg0,7571 %
   mixed fractions - disposalno use - 'hot technologies' TDTD100,0000 %9.250 kg0,7571 %
 
 collapse **19 12 04 / 05-1aPU foam < 0.2 % (H)CFC22,0000 %203.500 kg16,6563 %
  plastics cond. PUxx (DE)plastics conditioningI100,0000 %203.500 kg16,6563 %
 
 collapse ***19 12 04 / 05-1aPU foam < 0.2 % (H)CFC90,0000 %183.150 kg14,9907 %
  Oil binding xx (DE)production of oil binding materialF100,0000 %183.150 kg14,9907 %
   plastics / organic fractionsPU > used as oil binding material MRMR100,0000 %183.150 kg14,9907 %
 
 collapse ***19 12 12 / 01residues from separation - no hazardous substances and plastics below ROHS/REACH values10,0000 %20.350 kg1,6656 %
  div. MWI's (DE)hazardous waste incinerationF100,0000 %20.350 kg1,6656 %
   mixed fractions - disposalno use - 'hot technologies' TDTD100,0000 %20.350 kg1,6656 %
 
 collapse **19 12 12 / 01residues from separation - no hazardous substances and plastics below ROHS/REACH values3,0000 %27.750 kg2,2713 %
  landfill X (nat. market)landfillF100,0000 %27.750 kg2,2713 %
   mixed fractions - disposalno use - 'cold technologies' LDLD100,0000 %27.750 kg2,2713 %
 
 collapse *16 02 14 / 03-3cabinets' with other than PU foam insulation2,9984 %37.000 kg3,0284 %
  shredder A (nat. market)large shredder / separationI100,0000 %37.000 kg3,0284 %
 
 collapse **19 12 02 / 01-2iron fraction 'pure'60,0000 %22.200 kg1,8171 %
  div. steel mills (EU/EFTA)steel mill 'traditional'F100,0000 %22.200 kg1,8171 %
   Fe / stainless steelFe > Fe recovery MRMR100,0000 %22.200 kg1,8171 %
 
 collapse **19 12 03 / 03-2aluminium fraction 'pure' 4,0000 %1.480 kg0,1211 %
  diff. smelters (EU/EFTA)Al smelterF100,0000 %1.480 kg0,1211 %
   AlAl > Al recovery MRMR100,0000 %1.480 kg0,1211 %
 
 collapse **19 12 03 / 05-2copper and copper alloys 'pure'1,0000 %370 kg0,0303 %
  diff. Cu smelters (EU/EFTA)Cu smelter 'traditional'F100,0000 %370 kg0,0303 %
   CuCu > Cu recovery MRMR100,0000 %370 kg0,0303 %
 
 collapse **19 12 04 / 02-2hard plastics 'pieces' 'pure' - below ROHS/REACH valuesplastics fraction20,0000 %7.400 kg0,6057 %
  business incinerator A (nat. market)co-incineration - with ERF100,0000 %7.400 kg0,6057 %
   plastics / organic fractionsplastics > used for fuel substitution ERER100,0000 %7.400 kg0,6057 %
 
 collapse **19 12 12 / 01residues from separation - no hazardous substances and plastics below ROHS/REACH valuesall shredder wastes15,0000 %5.550 kg0,4543 %
  MWI Z (nat. market)municipal waste incinerationF100,0000 %5.550 kg0,4543 %
   mixed fractions - disposalno use - 'hot technologies' TDTD100,0000 %5.550 kg0,4543 %
 
 collapse *16 02 15* / 01-2 mercury containing 'parts' dismantled0,0041 %50 kg0,0041 %
  underground landfill xx (DE)special landfillF100,0000 %50 kg0,0041 %
   mixed fractions - disposalno use - 'cold technologies' LDLD100,0000 %50 kg0,0041 %
 
 collapse *16 02 16 / 05copper-rich' fraction from dismantlingCu pipes with ceramic fillers0,2500 %3.085 kg0,2525 %
  diff. Cu smelters (EU/EFTA)Cu smelter 'traditional'F100,0000 %3.085 kg0,2525 %
   CuCu > Cu recovery MRMR95,0000 %2.931 kg0,2399 %
   inorganic residuesinorganic residues > slag production (no use) TDTD5,0000 %154 kg0,0126 %
 
 collapse *16 02 16 / 10-1power supply cables0,2026 %2.500 kg0,2046 %
  Cable shredder A (nat. market)fine shredder / separationI100,0000 %2.500 kg0,2046 %
 
 collapse **19 12 03 / 02-1mix of non-ferrous metals 'not pure'30,0000 %750 kg0,0614 %
  Cu smelter 1 (DE)Cu smelter 'traditional'F100,0000 %750 kg0,0614 %
   CuCu > Cu recovery MRMR92,0000 %690 kg0,0565 %
   Fe / stainless steelFe > used as reducing agent/ smelting detergent MRMR3,0000 %23 kg0,0018 %
   organic residuesorganic residues > no definite use in smelter TDTD5,0000 %38 kg0,0031 %
 
 collapse **19 12 04 / 07-1cable plastics60,0000 %1.500 kg0,1228 %
  plastics rec1 (NL)production of other products of/with plasticsF100,0000 %1.500 kg0,1228 %
   plastics / organic fractionsplastics > feedstock substitution in production of other products of/with plastics MRMR100,0000 %1.500 kg0,1228 %
 
 collapse **19 12 12 / 01residues from separation - no hazardous substances and plastics below ROHS/REACH values10,0000 %250 kg0,0205 %
  business incinerator A (nat. market)co-incineration - with ERF100,0000 %250 kg0,0205 %
   plastics / organic fractionsplastics > used for fuel substitution ERER100,0000 %250 kg0,0205 %
 
 collapse *16 02 16 / 12compressors (excl. oil)17,9903 %222.000 kg18,1705 %
  diff. Cu smelters (non-EU/EFTA)Cu smelter 'traditional'F100,0000 %222.000 kg18,1705 %
   CuCu > Cu recovery MRMR10,0000 %22.200 kg1,8171 %
   Fe / stainless steelFe > Fe recovery MRMR88,0000 %195.360 kg15,9901 %
   organic residuesorganic residues > no definite use in smelter TDTD2,0000 %4.440 kg0,3634 %
 
 collapse *16 02 16 / 32-2flat glass 'parts' from dismantling 'pure'0,9724 %12.000 kg0,9822 %
  Glass XY (nat. market)other glass conditioningI100,0000 %12.000 kg0,9822 %
 
 collapse **19 12 05 / 01glass 'pieces' 'pure' - no hazardous substances98,0000 %11.760 kg0,9625 %
  Glass XY (nat. market)glass productionF100,0000 %11.760 kg0,9625 %
   glassglass > used as raw material in glass production MRMR100,0000 %11.760 kg0,9625 %
 
 collapse **19 12 12 / 01residues from separation - no hazardous substances and plastics below ROHS/REACH values2,0000 %240 kg0,0196 %
  landfill X (nat. market)landfillF100,0000 %240 kg0,0196 %
   mixed fractions - disposalno use - 'cold technologies' LDLD100,0000 %240 kg0,0196 %
 
 collapse *19 02 07* / 01 compressor oil - low halogen content0,4052 %5.000 kg0,4092 %
  business incinerator A (nat. market)co-incineration - with ERF100,0000 %5.000 kg0,4092 %
   plastics / organic fractionsoil fraction > used for fuel substitution ERER100,0000 %5.000 kg0,4092 %
 
 collapse *deducted from input20 03 01mixed municipal waste - deducted from inputcontents of appliances0,9921 %12.242 kg 

Legend: RU - reuse of components, MR - material recycling, ER - energy recovery, TD - thermal disposal, LD - other disposal, e.g. landfill disposal
WF-RepTool pro V 5.1 - © WEEE Forum