Active package | Id 29 | hard plastics 'pieces' 'not pure' - above ROHS/REACH values - hard plastics 'pieces' 'not pure' - above ROHS/REACH values | Weight (kg) |
First fractions | Overview | Graph | Final | Calculation | Analyze | Inspect | Usage |
WF-RepTool code | Name fraction | Remarks fraction | |
appliances & appliance-like sorted | |||
cooling & freezing appliances | |||
16 02 11* / 00 | mix of cooling & freezing appliances incl. CFC/HCFC/HFC appliances | mix of all kinds of cooling & freezing appliances including CFC/HCFC/HFC appliances, no sorting of appliances, e.g. forwarded based on capacity reasons or sorted from other collection categories (e.g. large equipment) [see if 'only' CFC/HCFC/HFC cooling & freezing appliances sorted - 16 02 11* / 01] |
|
16 02 11* / 01 | CFC/HCFC/HFC cooling & freezing appliances | cooling & freezing appliances containing CFC/HCFC/HFC in any part - i.e. in the cooling circuit and/or the PU foam insulation, e.g. appliances forwarded to 'further treatment' [see mix of non-CFC/HCFC/HFC appliances - 16 02 13* / 02, NH3 appliances 16 02 13* / 03, HC appliances - 16 02 13* / 04] [see CFC/HCFC/HFC separated - 14 06 01* / xx] |
|
16 02 11* / 03 | CFC/HCFC air conditioner appliances | air conditioner appliances containing CFC/HCFC sorted, e.g. for appliances forwarded | |
16 02 11* / 04 | HFC tumble dryer appliances | tumble dryer appliances containing HFC sorted, e.g. for appliances forwarded | |
16 02 11* / 05 | other appliances containing CFC, HCFC, HFC | other 'appliances' containing CFC, HCFC, HFC 'sorted', e.g. heat pumps info: please give a remark on the kind of appliances (remark field, 'internal name') |
|
16 02 13* / 02 | mix of non-CFC/HCFC/HFC cooling & freezing appliances | mix of non-CFC/HCFC/HFC cooling & freezing appliances, e.g. after sorting of CFC/HCFC/HFC cooling & freezing appliances (i.e. mix of NH3-, HC- and 'other' cooling & freezing appliances) [see CFC/HCFC/HFC cooling & freezing appliances - 16 02 11* / xx] [see NH3 appliances - 16 02 13* / 03, HC appliances - 16 02 13* / 04] |
|
16 02 13* / 03 | NH3 cooling appliances | NH3 cooling appliances, e.g. appliances forwarded to 'further treatment' [see NH3-CrO4-mixture separated - 14 06 03* / 01] |
|
16 02 13* / 04 | HC cooling & freezing appliances | HC cooling & freezing appliances containing HC in any part - i.e. in the cooling circuit and/or the PU foam insulation, e.g. appliances forwarded to 'further treatment' [see HC 'cabinets' (after step 1 treatment) containing HC in the PU foam insulation 16 02 14 / 03-2] [see mix of cooling & freezing appliances possibly containing HC and CFC/HCFC/HFC appliances - 16 02 11* / 00] [see CFC/HCFC/HFC appliances - 16 02 11* / 01] [see HC separated - 14 06 03* / 02 |
|
cabinets from cooling & freezing appliances | |||
16 02 11* / 02 | mix of 'cabinets' containing PU foam insulation (all - CFC/HCFC and HC) | mix of all kinds of 'cabinets' (i.e. appliances/casings after step 1 treatment) containing PU foam insulation (CFC/HCFC and HC), e.g. treated together in step 2 [see separated 'cabinets' with CFC/HCFC-PU foam insulation - 16 02 11* / 02-1, 'cabinets' with HC-PU foam insulation 16 02 14 / 03-2, 'cabinets' with other than PU foam insulation - 16 02 14 / 03-3] |
|
16 02 11* / 02-1 | cabinets' containing CFC/HCFC-PU foam insulation | cabinets' (i.e. appliances/casings after step 1 treatment) containing CFC/HCFC PU foam insulation, e.g. sorted 'cabinets' after first step treatment, only cabinets further treated in 2nd step or treated separately in 2n step [see mix of 'cabinets' with PU foam insulation - 16 02 11* / 02, 'cabinets' with HC-PU foam insulation - 16 02 14 / 03-2, 'cabinets' with other than PU foam insulation - 16 02 14 / 03-3] |
|
16 02 14 / 03-2 | HC 'cabinets' | cabinets' (i.e. appliances/casings after step 1 treatment) containing HC in the PU foam insulation (HC-PU foam), e.g. for 'cabinets' sorted and treated separately or forwarded [see 'cabinets' with CFC/HCFC PU foam insulation - 16 02 11* / 02-x or 'cabinets' with other than PU foam insulation - 16 02 14 / 03-3] |
|
16 02 14 / 03-3 | cabinets' with other than PU foam insulation | cabinets' (i.e. appliances/casings after step 1 treatment) with other than PU foam insulation, e.g. glass wool and polystyrene 'cabinets', i.e. after 1st step treatment; e.g. forwarded to shredders [see 'cabinets' with PU foam insulation - 16 02 11* / 02(-1)] |
|
other appliances sorted | |||
16 02 10* | appliances containing PCBs | appliances containing PCBs sorted (e.g. oil radiators), to be forwarded to 'further treatment' (e.g. separation of oil) or 'final disposal' [see heat transmission oil containing PCB separated - 13 03 01*] |
|
16 02 12* | appliances containing (free) asbestos | appliances containing (free) asbestos sorted (e.g. asbestos containing ovens), to be forwarded to 'further treatment' (e.g. separation of asbestos fibres) or 'final disposal' [see 'components' or 'fibres' dismantled/separated - 16 02 15* / 05-2] |
|
16 02 13* / 12 | radioactive appliances | appliances containing radioactive substances (e.g. smoke detectors) sorted, e.g. forwarded to 'further treatment' (dismantling) or to 'final processes' (e.g. safety disposal) [see radioactive components dismantled - 16 02 15* / 10] |
|